Field service software vs refrigerant compliance software
HVAC and refrigeration field service management (FSM) software runs the service business: booking the call, dispatching a technician to a down cooler, recording the work and invoicing. Some FSM tools also log refrigerant. ServiceTitan documents a custom Refrigerant Tracking form for pounds added, recovered, recycled or disposed of per equipment and job; BuildOps tracks refrigerant type, amount and activity by asset; and Commusoft logs the type and amount used on every asset.
Refrigerant compliance software does a different job. It keeps each appliance’s full charge, calculates the leak rate from every addition, compares it with the threshold for that appliance type, and tracks what has to happen next: repair within 30 days, verification tests, inspections, and the chronic-leaker report. None of the FSM tools above documents a leak rate calculation across a fleet of appliances, and ServiceTitan’s help page says its refrigerant workflow “does not guarantee regulatory compliance.”
Many teams run both: FSM software for the service work and a compliance tool as the system of record for refrigerant. If you are choosing the FSM side, see our refrigeration service management software guide or the HVAC software guide.
What EPA rules require you to record in 2026
Two federal programs apply, and the refrigerant decides which one. This is general information from the regulation text, not legal or compliance advice.
- Ozone-depleting refrigerants (such as R-22): Clean Air Act Section 608 leak repair rules (40 CFR 82.157) apply to appliances with a full charge of 50 pounds or more. Since April 10, 2020 they do not apply to appliances containing only substitute refrigerants.
- HFCs and substitutes with a global warming potential above 53: the AIM Act Emissions Reduction and Reclamation rule (40 CFR 84.106) has applied since January 1, 2026 to appliances with a full charge of 15 pounds or more. It excludes appliances that contain only an ozone-depleting refrigerant and the residential and light commercial air conditioning and heat pump subsector.
The thresholds are the same under both programs. Above them, leaks must be repaired within 30 days, or 120 days if an industrial process shutdown is needed. For HFC appliances, the owner or operator must run initial and follow-up verification tests on each repair. The parts of the HFC rule that software has to support are:
- A leak rate at every addition. The owner or operator must calculate the leak rate every time refrigerant is added, except after a retrofit, a new installation or a seasonal variance, using the annualizing or rolling average method.
- Full-charge records. By January 1, 2026, or at installation, owners must determine the full charge of every appliance of 15 pounds or more, record how it was determined, and keep that record until three years after the appliance is retired.
- A record for every service. Each installation, service, repair or disposal needs the appliance and location, date, parts, type of work, technician name, amount and type of refrigerant added or removed, full charge, and the leak rate with the method used. Technicians must give the owner this documentation when the work is done.
- Three-year retention. Records are kept at least three years, on paper or electronically.
- Chronic leakers. Appliances of 15 pounds or more that leak 125% or more of their full charge in a calendar year must be reported to EPA by March 1 of the next year.
- Inspections and leak detection. After a leak above the threshold, commercial and industrial process refrigeration appliances of 500 pounds or more need leak inspections every three months until four quarters pass under the threshold. Systems of 1,500 pounds or more must install automatic leak detection, audited and calibrated annually: new systems from January 1, 2026, and systems installed from 2017 through 2025 by January 1, 2027.
What changed in 2026. In May 2026 EPA finalized changes to its Technology Transitions rule, which governs the refrigerants allowed in new equipment, and proposed exempting road and intermodal transport refrigeration units from the HFC leak repair rule. As of November 17, 2026, the Federal Register shows that exemption as a proposed rule only, and we found no final amendment to the leak repair section itself. States can go further: California’s Refrigerant Management Program covers systems with more than 50 pounds of high-GWP refrigerant and has its own reporting through CARB’s R3 tool.
Fexa Trakref
Best fit: multi-site brands and the contractors who service them. Fexa acquired Trakref in 2023 and now sells it as Fexa Trakref, describing it as “built for multi-site brands and contractors.” Its compliance center tracks leak repair deadlines, leak rate exceedances, chronically leaking systems, failed leak verification and ALD calibration, and it exports EPA 608, California CARB and EPA GreenChill reports. It covers refrigerant inventory, cylinder moves and recycling, and appliance disposals, and its mobile app supports offline data entry. Integrations: an API to sync with third-party CMMS or facilities systems, plus Fexa’s own CMMS. Limitation: no published price.
Sphera Refrigerant Compliance Management
Best fit: environmental, health and safety (EHS) teams that want refrigerant inside wider environmental reporting. Sphera lists the product under its environmental accounting software and documents leak rate calculations, automatic alerts, verification testing on repairs, scheduled inspections and automatic leak detection. It positions the tool for Clean Air Act Title VI, Toxics Release Inventory, California AB 32 and EU F-Gas. Limitation: the product page does not state mobile use, integrations or price, and does not name the AIM Act, so ask how it handles the 15-pound HFC records.
Accruent Sustain
Best fit: multi-location enterprises; Accruent’s featured customer quote comes from a grocery retailer, and it calls Sustain the longest-standing refrigerant management application on the market. It captures system details, gas types and volumes, technician certifications, and leak rate alerting with follow-up checks, and says staff can enter data from a mobile device. Integrations: Accruent says Sustain can integrate with your CMMS or mobile workforce management system. Limitation: no published price, and the page describes Section 608 configuration without naming the AIM Act HFC rule.
MSA Parasense
Best fit: equipment owners and refrigeration contractors, from a single site to an enterprise rollout. MSA documents an automated leak rate calculator, a compliance calendar, an asset database by make, model and refrigerant type, and a “Refrigerant Bank and Bottles” feature for stored refrigerant, with EPA compliance and CARB XML reports. Pricing is by quote, but MSA says there is “no user limit or cost per user fee.” Integrations: JLL built its Corrigo refrigerant tracking add-on on Parasense. Limitation: the pages we checked do not describe a mobile app.
ServiceChannel Refrigerant Tracking
Best fit: multi-location businesses already using ServiceChannel to manage facilities work orders. The module tracks racks, circuits and components with charge levels, calculates leak rates automatically, schedules follow-up verification, and generates EPA, AIM Act, GreenChill, state-level and EU F-Gas reporting. Contractors work through ServiceChannel’s Provider App, and staff can scan asset tags on mobile. Limitation: it is a module of a larger facilities platform with no published price, so it is a poor fit as a standalone tool.
FMHero
Best fit: technicians and contractors who want to start small. The technician app is free and covers nameplate scanning, refrigerant and cylinder tracking, and real-time leak rate calculations with exceedance warnings; FMHero also says it tracks repair deadlines. HeroPro costs $15/month for a single user, and Team $25 per field user per month, both paid yearly; web and office users are free, and facility plans are quoted. Limitation: FMHero describes “audit-ready compliance reports” but does not name the report formats (EPA, AIM Act or CARB), and no integrations are named.
Ref LeakLog
Best fit: small HVAC/R contractors and building owners focused on the federal HFC rule. It builds in both the annualizing and rolling average leak rate methods, starts a 30-day repair countdown when a unit crosses its threshold, logs verification tests, runs the 125% chronic-leaker test, and produces PDF compliance reports. It costs $29/month for one user, $59 for up to three and $89 for up to eight, with a 14-day free trial. Limitation: it does not integrate with dispatch software (its FAQ says technicians log the service event on their phone after the call), cylinder tracking and CARB reports are not stated, and it runs in the browser rather than as a separate app.
Which refrigerant tracking software fits your business